Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Arq. bras. oftalmol ; 87(2): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533793

ABSTRACT

ABSTRACT Purpose: To determine the absorbance coefficient of the thin porcine cornea to ultraviolet-A radiation (365 nm) submitted for crosslinking. Methods: This in vitro, benchtop experiment using cadaver tissue study analyzed 12 porcine corneal lamellas, which were obtained using a microkeratome after mechanical de-epithelization and separated into three thickness groups: 180, 300, and 360 μm. The corneal thickness values were measured by anterior-segment optical coherence tomography. All lamellas had ultraviolet-A (365 nm) absorbance measured with a 96-well plate spectrophotometer using an ultraviolet transparent microplate before riboflavin instillation and preand post-crosslinking according to the Dresden protocol. Results: The ultraviolet absorbance profiles of the 180, 300, and 360 μm groups were obtained as α-coefficients of 12.85, 76.55, and 120.27, respectively. A theoretical formula was calculated though a statistical analysis that demonstrated the correlation between stromal lamellar thickness and ultraviolet absorbance. Conclusions: Corneal thickness and ultraviolet-A spectral absorbance of corneal lamellas showed linear correlation. These findings can potentially contribute to the optimization of ultraviolet-A application during crosslinking, making the treatment of corneas with thickness <400 μm safe and personalized energy delivery for each corneal thickness.

2.
Arq. bras. neurocir ; 40(2): 152-158, 15/06/2021.
Article in English | LILACS | ID: biblio-1362205

ABSTRACT

There are four types of anastomoses between themedian and ulnar nerves in the upper limbs. It consists of crossings of axons that produce changes in the innervation of the upper limbs, mainly in the intrinsic muscles of the hand. The forearm has two anatomical changes ­ Martin-Gruber: branch originating close to the median nerve joining distally to the ulnar nerve; and Marinacci: branch originating close to the ulnar nerve and distally joining the median nerve. The hand also has two types of anastomoses, which are more common, and sometimes considered a normal anatomical pattern ­ Berrettini: Connection between the common digital nerves of the ulnar and median nerves; and Riche-Cannieu: anastomosis between the recurrent branch of the median nerve and the deep branch of the ulnar nerve. Due to these connection patterns, musculoskeletal disorders and neuropathies can be misinterpreted, and nerve injuries during surgery may occur, without the knowledge of these anastomoses. Therefore, knowledge of them is essential for the clinical practice. The purpose of the present review is to provide important information about each type of anastomosis of the median and ulnar nerves in the forearm and hand.


Subject(s)
Arteriovenous Anastomosis/anatomy & histology , Ulnar Nerve/anatomy & histology , Median Nerve/anatomy & histology , Axons , Hand Joints/innervation , Forearm/innervation
3.
Acta sci. vet. (Impr.) ; 49: Pub. 1832, 2021. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1363713

ABSTRACT

Veterinary Ophthalmology provides complementary information for the diagnosis of ocular pathologies. Studies in wild species are essential. Among the diagnostic techniques in ophthalmology, two-dimensional ultrasonography stands out. The agouti is a rodent belonging to the Dasyproctidae family that has been widely used as an experimental model. For these animals, sight is one of the crucial senses for their survival. The aim of this study was to evaluate the effectiveness of the two-dimensional ocular ultrasound technique to obtain anatomical measurements and the external ophthalmic artery resistivity index, presumably normal in the species Dasyprocta prymnolopha. Forty eye bulbs of 20 adult rodents of the species were evaluated by ultrasonography. In these animals, B-mode echobiometry was performed using the transpalpebral approach and the hemodynamic study of the external ophthalmic artery using the color Doppler technique. All examinations were initiated by the left eye bulb and all measurements were performed by only one examiner. The collected data related to echobiometry were analyzed using Bioest 5.0 for Windows. Initially, normality was tested using the Shapiro-Wilk test for each parameter, then the paired t-test was performed, comparing right and left eyes, and a significance level of 5% (P < 0.05) was adopted. Based on the methodology used, the following values were obtained for the right and left eyeballs, respectively: anterior chamber thickness - mean of 1.28 ± 0.3 mm and 1.22 ± 0.1 mm; lens thickness - 8.27 ± 0.9 mm and 8.11 ± 0.9 mm; vitreous chamber thickness - 5.35 ± 0.48 mm and 5.30 ± 0.47 mm and axial length - 12.7 ± 0.9 mm and 13 ± 0.68 mm. The mean external ophthalmic artery resistivity values were 0.4305 ± 0.0390 and 0.4258 ± 0.0387 (right and left eye, respectively), characterizing a low resistance. There was no statistical difference between the right and left eyeballs in any of the studied parameters. The use of the convex transducer was feasible, promoting adequate contact with the ocular surface and images of satisfactory quality for obtaining measurements, similar to what was observed in studies evaluating the ocular biometry of primates and dogs. The anterior chamber thickness values in this experiment did not differ statistically between the antimers, as well as observed for dogs. The data obtained for lens thickness did not differ statistically for antimers, like those obtained for other rodent species evaluated with the same methodology. The mean values of vitreous chamber thickness were like those observed in chinchillas but correspond to about half of that obtained for capybaras. In this study, the external ophthalmic artery was characterized in all animals, but obtaining the spectral tracing was difficult due to its fine caliber. In wild animals, and especially in wild rodents, there are few data reporting the resistivity of the ophthalmic artery, and there is a lack of studies, which can be explained by the behavioral characteristics of defense and by the high susceptibility to stress in capture, since the performing the technique requires, as in other procedures, the use of chemical containment. (AU)


Subject(s)
Animals , Ophthalmic Artery/anatomy & histology , Ophthalmic Artery/diagnostic imaging , Dasyproctidae , Ultrasonography/veterinary , Animals, Wild
4.
Rev. méd. Minas Gerais ; 31: 31403, 2021.
Article in Portuguese | LILACS | ID: biblio-1291367

ABSTRACT

Cistos iridociliar são lesões raras, em geral assintomáticas de ocorrência esporádica. Caracteriza-se por lesões globulares originadas em epitélio de íris e corpo ciliar. Trata-se de um caso raro de cisto iridociliar de origem primária, sem relação traumática ou medicamentosa, em paciente adulto jovem. Foi-se realizado exame clínico em consultório oftalmológico com suspeita de lesão em topografia de olho esquerdo, confirmada posteriormente em exame de ultrassom de alta resolução,a biomicroscopia ultrassônica. O tratamento instituído foi de acompanhamento médico continuado, devido ao risco de evolução com comprometimento da saúde ocular, entre eles obstrução visual aguda e glaucoma por fechamento angular grave.


Iridociliary cysts are rare lesions, usually asymptomatic and sporadic. It is characterized by globular lesions originating in iris epithelium and ciliary body. It is a rare case of iridociliary cyst of primary origin, without a traumatic or medication relationship, in a young adult patient. A clinical examination was carried out in an ophthalmology office with suspicion of a lesion in the topography of the left eye, which was later confirmed in a high-resolution ultrasound examination, ultrasound biomicroscopy. The treatment instituted was continuous medical follow-up, due to the risk of progression with impaired eye health, including acute visual obstruction and glaucoma due to severe angular closure.


Subject(s)
Female , Adult , Cysts , Iris Diseases , Ophthalmology , Wounds and Injuries , Iris , Ciliary Body , Eye Health , Slit Lamp Microscopy
5.
Arch. Health Sci. (Online) ; 27(1)jan-mar.2020.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1369545

ABSTRACT

Introdução: As próteses são definidas como dispositivos destinados a suprir a funcionalidade completa ou parcial de um membro ausente, de forma a prover independência ao indivíduo amputado, além de melhorar aspectos psicológicos e sociais. Portanto, a escolha da prótese adequada tem um papel fundamental no processo de reabilitação desses pacientes. Nesse contexto, a tecnologia de impressão tridimensional (3D) aplicada na área da saúde tem agregado novas possibilidades na fabricação de próteses. Objetivo: Analisar as evidências da utilização de próteses fabricadas utilizando a tecnologia de impressão 3D em amputados. Métodos: Trata-se de uma revisão de literatura de artigos científicos indexados nas bases de dados MEDLINE, SciELO e LILACS. A pesquisa foi realizada sem restrição de data ou idioma, com base na combinação das palavras-chave: amputação, próteses, impressão tridimensional e membros artificiais. Resultados: A análise foi desenvolvida utilizando 13 artigos que apresentaram como principais vantagens das próteses fabricadas em impressão 3D o baixo custo e menor tempo de fabricação, personalização, manutenção barata, próteses mais leves, modelos digitais de próteses disponíveis gratuitamente e possibilidade de agregar outros sistemas como polias e sistemas mioelétricos. As desvantagens incluem próteses com materiais menos duráveis, menos rígidos, com pouca estabilidade térmica, além de apresentarem baixa força de preensão manual e necessidade de mais profissionais qualificados para o processo de fabricação. Conclusão: As próteses desenvolvidas utilizando a tecnologia de impressão 3D melhoram a qualidade de vida em indivíduos com deficiência física, permitindo-os executar ações perdidas pela ausência do membro. Embora exista alguns obstáculos e desvantagens, a tecnologia de impressão 3D tem emergido como potencial ferramenta para construção de próteses personalizadas e mais acessíveis.

6.
Pesqui. vet. bras ; 38(8): 1705-1711, Aug. 2018. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-976490

ABSTRACT

Wild species, especially those threatened with extinction, are increasingly being investigated to obtain information that can be useful for their preservation. The objective of the present study was to standardize the vertebral heart scale (VHS) and cardiothoracic ratio (CTR) of the collared peccary (Tayassu tajacu Linnaeus, 1758) sedated with ketamine and midazolam. Fourteen clinically healthy collared peccaries were examined in the two-year age group weighing 15-22kg. The animals were submitted to digital radiography of the thorax in lateral and dorsal ventral projections to calculate the VHS and CTR. The VHS mean values for males and females was 8.88±0.51v for right recumbency and 8.84±0.39v for left decubitus, and there were no significant between-gender differences regarding recumbency (p>0.05). The CTR showed mean values of 0.50±0.05 (males) and 0.45±0.04 (females), but the gender-differences were not significant (p>0.05). A positive correlation was shown between VHS and CTR (r=0.98, right decubitus; r=0.96, left decubitus). Establishing reference values for heart measurements in collared peccaries using digital radiography of the thorax permitted standardization of the VHS and CTR values for this wild species. In the studied wild animal model, the VHS and CTR heart assessment indexes were shown to be essential diagnostic tools for investigations of alterations in the size of the cardiac silhouette.(AU)


Espécies silvestres têm sido cada vez mais exploradas como forma de obter informações que favoreçam sua conservação, especialmente aquelas ameaçadas de extinção. Este trabalho teve por objetivo a padronização dos valores de VHS (vertebral heart scale) e índice cardiotorácico (ICT) de catetos (Tayassu tajacu Linnaeus, 1758) contidos com Cetamina e Midazolam. Foram avaliados 14 catetos clinicamente saudáveis, com faixa etária de 2 anos e variação média de peso entre 15 a 22Kg. Os animais foram submetidos a radiografia digital de tórax em projeções laterolaterais e dorsoventrais para o cálculo do vertebral heart scale (VHS) e Índice Cardiotorácico (ICT). O VHS evidenciou valores médios entre machos e fêmeas de 8,88±0,51v para decúbito direito e 8,84±0,39v para decúbito esquerdo, não ocorrendo diferença estatística entre os decúbitos (p>0,05). O ICT revelou valores médios de 0,50±0,05 (machos) e de 0,45±0,04 (fêmeas), não sendo verificada diferença estatística significativa entre os sexos (p>0,05). Verificou-se correlação positiva entre VHS e o ICT (r=0,98, decúbito direito, r= 0,96, decúbito esquerdo). O estabelecimento dos valores de referência para mensurações cardíacas em catetos, a partir de radiografias digitais do tórax, permitiu a padronização do VHS e ICT para esta espécie silvestre. No modelo animal silvestre estudado, os índices de avaliação cardíaca VHS e ICT mostraram-se como uma ferramenta diagnóstica imprescindível para investigações sobre as alterações do tamanho da silhueta cardíaca.(AU)


Subject(s)
Animals , Artiodactyla/anatomy & histology , Cardiology/methods , Midazolam , Animals, Wild/classification
7.
Pesqui. vet. bras ; 38(4): 785-793, abr. 2018. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-955376

ABSTRACT

Agoutis are small-sized wild animals whose body weight can reach up to 4kg, and are found throughout Brazil. They are considered important seed dispersers, especially for big trees and there are species that rely almost exclusively on these animals for their territorial distribution. The objective of the present study was B scan and Doppler ultrasound characterization of the abdominal organs of healthy agoutis reared in captivity. Fifteen agoutis, chemically restrained, were used from the Nucleus for Wild Animal Studies and Conservation (Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS), CCA-UFPI, submitted to B scan and Doppler ultrasound examination. The urinary bladder wall was hyperechogenic, thin, smooth and regular throughout its anatomic path, with 0.09±0.03cm mean thickness. The kidneys showed fine and homogeneous echotexture, preserved global echogenicity, hyperechogenic in relation to the spleen and isoechogenic or discreetly hyperechogenic in relation to the liver. The spectral Doppler trace showed systolic and diastolic peaks, wide and thread-like, with low flow resistance and a continuous and full diastolic portion that decreased gradually during the diastole (75.83±1.42cm/s, for the right kidney and 80.43±1.22cm/s, for the left kidney). The right adrenal gland was 0.61-1.18cm long and 0.17-0.32cm in diameter, while the left adrenal gland was 0.62-1.16 long with 0.14-0.25cm diameter. The agouti spleen was filiform in shape, with pointed poles and 1.02±0.18cm in diameter. The agouti liver occupied all the abdominal cavity cranial space in direct contact with the diaphragm. The intrahepatic vascular flow allowed individualization of the portal vein (PV) and hepatic vein (HV). The portal veins were distinguished from the hepatic veins mainly by their wall echogenic pattern. The pancreas was 0.51±0.1 cm thick and the pancreatic duct measured 0.12±0.02cm. The stomach was placed to the left the spleen and to the right of the proximal intestine and the transversal colon and the walls were 0.16±0.05cm thick. The abdominal aorta was 0.43±0.04cm in diameter and showed 95.2±2.16cm/s vascular flow. This study characterized agouti organs and abdominal blood vessels by B scan and Doppler ultrasound, that permitted definition of the size, shape, position, echogenicity and echotexture of the anatomic constituents and established reference values for the vascular network and blood flow in the species.(AU)


As cutias são animais silvestres de pequeno porte, cujo peso corpóreo pode chegar até 4kg, e existem em todo território brasileiro. São considerados importantes dispersores de sementes, especialmente para árvores de grande porte, existindo espécies que dependem quase que exclusivamente destas para sua distribuição territorial. Este trabalho teve por objetivo a caracterização ultrassonográfica modo B e Doppler dos órgãos abdominais de cutias hígidas criadas em cativeiro. Foram utilizadas 15 cutias, contidas quimicamente, oriundas do Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS, CCA-UFPI, submetidas a exame ultrassonográfico em modo B e Doppler. A parede da vesícula urinária presentou-se hiperecogênica, fina, lisa e regular em todo seu trajeto anatômico, com espessura média de 0,09±0,03cm. Os rins demonstraram ecotextura fina e homogênea, ecogenicidade global preservada, hipoecogênico em relação ao baço e isoecogênico ou discretamente hipoecogênico em relação ao fígado. O traçado em Doppler espectral mostrou pico sistólico e diastólico, amplo e afilado, exibindo baixa resistência de fluxo, com uma porção diastólica contínua e cheia, que diminui gradativamente no decorrer da diástole (75,83±1,42cm/s para o rim direito e 80,43±1,22 cm/s para o esquerdo. A adrenal direita apresentou uma variação de comprimento entre 0,61 a 1,18cm e diâmetro variando entre 0,17 a 0,32cm, enquanto a adrenal esquerda evidenciou comprimento de 0,62 a 1,16 e diâmetro de 0,14 a 0,25cm. O baço das cutias mostrou formato filiforme, com polos pontiagudos e diâmetro de 1,02±0,18cm. O fígado da cutia ocupa todo o espaço cranial da cavidade abdominal, em contato direto com o diafragma. O fluxo vascular intrahepático permitiu individualizar as veias porta (VP) e veias hepáticas (VH). As veias porta foram distinguidas, particularmente pelo padrão ecogênico de suas paredes, quando comparadas com as veias hepáticas. A espessura do pâncreas foi de 0,51±0,1cm e o ducto pancreático mediu 0,12±0,02cm. O estômago relaciona-se à esquerda com o baço e a direita com o duodeno proximal e colón transverso. Sua espessura de parede mensurada foi de 0,16±0,05cm. A aorta abdominal possui diâmetro de 0,43±0,04cm e fluxo vascular de 95,2±2,16cm/s. Este estudo caracterizou os órgãos e vasos sanguíneos abdominais de cutias, por meio de ultrassonografia modo B e Doppler, o que permitiu definir o tamanho, formato, posição, ecogenicidade, ecotextura dos constituintes anatômicos, além de estabelecer valores de referência para a rede vascular e fluxo sanguíneo na espécie.(AU)


Subject(s)
Animals , Ultrasonography/statistics & numerical data , Ultrasonography/veterinary , Dasyproctidae/anatomy & histology
8.
ABC., imagem cardiovasc ; 31(1): f:57-l:66, jan.-mar. 2018. ilus, tab
Article in Portuguese | LILACS | ID: biblio-878762

ABSTRACT

Introdução: O macaco-capuchinho é uma espécie de primata não humano que demonstra grande potencial para estudos pré-clínicos devido às semelhanças anatômicas e fisiológicas com os seres humanos. Objetivo: Estudar os índices de deformação miocárdica em macacos-capuchinhos anestesiados utilizando speckle tracking. Métodos: Foram utilizados dezesseis animais do Parque Zoobotânico, em Teresina, Piauí, Brasil, com restrição química, utilizando uma combinação de cetamina e midazolam. Os estudos ecocardiográficos foram obtidos nos modos B, M e Doppler, medindo-se strain e strain rate através de speckle tracking. Resultados: As variáveis que apresentaram coeficientes de correlação estatisticamente significativos em relação ao peso foram a parede livre do ventrículo esquerdo em diástole (PLVEd), diâmetro interno do ventrículo esquerdo em diástole (DIVEd), diâmetro interno do ventrículo esquerdo em sístole (DIVEs), onda E, A'VD, movimento do anel mitral (MAM) e excursão sistólica do plano do anel tricúspide (TAPSE). A frequência cardíaca (FC) mostrou correlação positiva com a onda E e a onda A e correlação negativa com o tempo de relaxamento isovolumétrico (TRIV). A fração de encurtamento (FS) apresentou correlação positiva com a razão entre as ondas E e A (r = 0,61). TAPSE mostrou correlações positivas com E'VD e A'VD. Os valores obtidos para o strain circunferencial (-18,17 ± 4,68%), radial (47,13 ± 5,24%) e longitudinal (-26,46 ± 5,155%) para os macacos-capuchinhos estavam dentro dos intervalos normais para machos e fêmeas. Conclusão: O presente estudo fornece os primeiros valores de referência para medidas ecocardiográficas em modos B, M e Doppler para macacos-capuchinhos anestesiados com cetamina e midazolam. Os valores de strain e strain rate obtidos utilizando a técnica de speckle tracking mostraram-se semelhantes aos obtidos em seres humanos, sugerindo que esta ferramenta pode ser explorada em estudos pré-clínicos utilizando o modelo do macaco-capuchinho


Introduction: The capuchin monkey is a type of nonhuman primate that has shown great potential for preclinical studies because of its anatomical and physiological similarities to humans. Objective: To study the indices of myocardial deformation in anesthetized capuchin monkeys using speckle tracking. Methods: Sixteen animals from the Zoobotanical Park, Teresina, Piauí, Brazil, were used and chemically restrained using a combination of ketamine and midazolam. Echocardiography recordings were obtained in B, M and Doppler modes, and strain and strain rate were measured using speckle tracking. Results: The variables that showed statistically significant correlation coefficients in relation to weight were LVFWd, LVIDd, LVIDs, E wave, A'RV, MAM and TAPSE. HR showed a positive correlation with the E wave and A wave and a negative correlation with IVRT. FS presented a positive correlation with the E/A wave relationship (r = 0.61). TAPSE showed positive correlations with E'RV and A'RV. The values obtained for circumferential (-18.17 ± 4.68%), radial (47.13 ± 5.24%) and longitudinal (- 26.46 ± 5.15%) strain for the capuchin monkeys were within the normal ranges for males and females. Conclusion: The present study provides the first reference values for echocardiographic measurements in B, M and Doppler modes for capuchin monkeys anesthetized with ketamine and midazolam. The strain and strain rate values obtained using speckle tracking showed similarities with those obtained in humans, suggesting that this tool has the potential to be exploited in preclinical studies using the capuchin monkey model


Subject(s)
Animals , Anesthetics, Intravenous/therapeutic use , Echocardiography/methods , Models, Animal , Myocardial Contraction , Diagnostic Imaging , Echocardiography, Doppler/methods , Heart Defects, Congenital/genetics , Heart Rate , Heart Ventricles , Hematologic Tests/methods , Ketamine/therapeutic use , Midazolam/therapeutic use , Guidelines as Topic/methods , Data Interpretation, Statistical
9.
Pesqui. vet. bras ; 38(3): 565-571, mar. 2018. ilus, tab
Article in English | LILACS, VETINDEX | ID: biblio-966942

ABSTRACT

B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.


O exame ultrassonográfico modo-B é uma importante ferramenta diagnóstica que permite caracterizar a anatomia interna dos órgãos e, complementada pelo exame modo Doppler, possibilita realizar a avaliação hemodinâmica vascular, aumentando a acurácia diagnóstica. Desta forma, este trabalho teve como objetivo a caracterização ultrassonográfica e mensuração dos segmentos do bulbo ocular modo-B, assim como a avaliação da artéria oftálmica externa pelo Doppler colorido e pulsado. Foram avaliados 60 bulbos oculares de 30 cães de diferentes raças utilizando transdutor microconvexo de 8,5MHz. Inicialmente foi realizada biometria por meio do exame em modo-B dos seguintes seguimentos: comprimento axial (M1), profundidade da câmara anterior (M2), espessura da lente (M3), comprimento da lente (M4), profundidade da câmara vítrea (M5), comprimento do disco óptico (M6) e diâmetro do nervo óptico (M7). A artéria oftálmica externa foi identificada pelo Doppler colorido e seu fluxo foi avaliado por meio do Doppler pulsado, sendo mensurados: velocidade do pico sistólico (VPS), velocidade diastólica final (VDF), índice de resistividade (IR) e índice de pulsatilidade (IP). Não foi verificada diferença estatística para os valores biométricos dos seguimentos oculares entre os olhos direito e esquerdo (p>0,05). A profundidade da câmera vítrea (M5), mostrou-se a variável biométrica com maior simetria bilateral, variando entre 0,79 a 0,87cm e 0,78 a 0,86cm para o olho direito e esquerdo, respectivamente. A artéria oftálmica foi visibilizada sobre o nervo óptico em direção ao bulbo ocular, com fluxo marcado em vermelho. Não houve diferença estatística significativa entre os valores Dopplervelocimétricos da artéria oftálmica entre do olho direito e esquerdo dos animais avaliados (p>0.05). O índice de resistividade (IR) médio evidenciou valores médios sendo igual a 0,63±0,03, bilateralmente. A velocidade basal média foi 17,50cm/s e 18,18cm/s no pico sistólico e 6,21cm/s e 6,68cm/s no final da diástole, para os olhos direito e esquerdo, respectivamente. A caracterização anatômica, biométrica e hemodinâmica utilizando o exame ultrassonográfico modo-B e as modalidades do Doppler permitiram a avaliação ultrassonográfica e Dopplervelocimétrica dos componentes do bulbo ocular nos cães de diferentes raças, podendo ser utilizados na rotina clínica oftalmológica para identificação de patologias oculares.


Subject(s)
Animals , Dogs , Ultrasonography, Doppler, Color/veterinary , Diagnostic Techniques, Ophthalmological/veterinary , Hemodynamics , Dogs
10.
Pesqui. vet. bras ; 37(2): 150-155, fev. 2017. ilus, tab
Article in English | LILACS, VETINDEX | ID: biblio-834002

ABSTRACT

An electrocardiogram is a test that assesses heart electrical activity and is applied more frequently in the veterinary care of wild animals. The present study aimed to define the electrocardiogram pattern of agoutis (Dasyprocta prymnolopha Wagler, 1831) anesthetized with ketamine and midazolam. Eighteen clinically healthy agoutis (D. prymnolopha) were used from the Nucleus for Wild Animal Studies and Conservation (NEPAS) of the Federal University of Piauí, Brazil. The animals were chemically restrained with 5% ketamine hydrochloride at a dose of 15mg/kg and midazolam at a dose of 1mg/kg by intramuscular injection. Electrocardiogram tests were carried out by a computerized method with the veterinary electrocardiogram [Acquisition Model for Computer (ECG - PC version Windows 95) Brazilian Electronic Technology (TEB) consisting of an electronic circuit externally connected to a notebook computer with ECGPC-VET (TEB) software installed on the hard disc. In analysing the EKG results, significant differences were observed for QRS complex duration, PR and QT intervals and for R wave millivoltage between the genders; but we observed a significant influence of weight despite the gender. In the present experiment, the anaesthetic protocol was shown to be well tolerated by the agoutis, and no arrhythmias occurred during the time the animals were monitored. The reference values obtained should be used to better understand the cardiac electrophysiology of the species and for its clinical and surgical management.(AU)


O eletrocardiograma computadorizado é um dos meios de diagnóstico utilizado para avaliação do coração e vem sendo cada vez mais presente na rotina veterinária. Este trabalho teve por objetivo definir o padrão eletrocardiográfico de cutias (D. prymnolopha) anestesiadas com cetamina e midazolam. Foram utilizadas 18 cutias clinicamente saudáveis, provenientes do Núcleo de Estudos e Preservação de Animais Silvestres (NEPAS) da Universidade Federal do Piauí. Os animais foram submetidos à contenção química com cloridrato de cetamina a 5% na dosagem de 15mg/kg associado ao midazolam, na dosagem de 1mg/kg, por via intramuscular. Os exames eletrocardiográficos foram realizados pelo método computadorizado, com o eletrocardiógrafo veterinário (Módulo de Aquisição de ECG Para Computador (ECG - PC versão Windows 95) Tecnologia Eletrônica Brasileira (TEB) composto por um circuito eletrônico ligado externamente a um notebook, e de um software instalado no disco rígido do computador. Os valores de duração do complexo QRS, intervalos PR e QT, comparados entre machos e fêmeas, apresentaram diferença significativa. Em milivoltagem a onda R foi o único parâmetro que apresentou diferença significativa entre machos e fêmeas. O peso dos animais também foi significativamente diferente entre os gêneros. O protocolo anestésico mostrou-se bem tolerado pelos animais deste experimento, não ocorrendo quadros de arritmias durante o tempo de monitoramento dos animais.(AU)


Subject(s)
Animals , Anesthetics/analysis , Dasyproctidae , Electrocardiography/veterinary , Ketamine , Midazolam , Animals, Wild , Reference Values
11.
Pesqui. vet. bras ; 35(10): 853-858, out. 2015. tab, graf
Article in English | LILACS | ID: lil-767748

ABSTRACT

The VHS and CTR were assessed using computerized thoracic radiographs of ten clinically healthy tufted capuchin monkeys (five males and five females) from the Wild Animal Screening Center in São Luís (Centro de Triagem de Animais Silvestres de São Luís-MA-CETAS). Radiographs were taken in laterolateral and dorsoventral projections to calculate the cardiothoracic ratio (VHS) and vertebral heart size (CTR). The VHS showed mean values of 9.34±0.32v (males) and 9.16±0.34v (females) and there was no statistical difference between males and females (p>0.05). The CTR showed mean values of 0.55±0.04 (males) and 0.52±0.03 (females) and there was no statistical difference between the sexes (p>0.05). There was positive correlation between VHS and CTR (r=0.78). The thoracic and heart diameters showed mean values of 5.70±0.48cm and 2.16±0.40cm in the males, respectively. In the females they measured 5.32±0.39cm and 2.94±0.32cm. There was no statistical difference between the sexes. Our results show that the high correlation found between VHS and CTR permitted the verification with similar clinical precision between the two methods to estimate alterations in the heart silhouette by radiographic examination of tufted capuchin, making it an easy technique to apply that can be considered in the investigation of heart problems for this wild species...


Para a avaliação do VHS e ICT foram utilizadas radiografias torácicas computadorizadas de 10 macacos-prego (05 machos e 05 fêmeas) clinicamente saudáveis, oriundos do Centro de Triagem de Animais Silvestres de São Luís-MA-CETAS. Foram tomadas radiografias em projeções laterolaterais e dorsoventrais, para cálculo do Vertebral Heart Scale (VHS) e Índice Cardiotorácico (ICT). O VHS evidenciou valores médios de 9,34±0,32v (machos) e 9,16±0,34v (fêmeas), não ocorrendo diferença estatística entre machos e fêmeas (p>0,05). O ICT evidenciou valores médios de 0,55±0,04 (machos) e de 0,52±0,03 (fêmeas), não sendo verificada diferença estatística entre sexos (p>0,05). Verificou-se correlação positiva entre VHS e ICT (r=0,78). Os diâmetros torácico e cardíaco demonstraram valores médios de 5,70±0,48cm e 3,16±0,40cm nos machos, respectivamente. Nas fêmeas mediram 5,32±0,39cm e 2,94±0,32cm. Não houve diferença estatística entre os sexos (p>0,05). Os nossos resultados demonstraram que a alta correlação encontrada entre o VHS e o ICT permitiu verificar precisão clínica semelhante entre os dois métodos, para estimar alterações da silhueta cardíaca ao exame radiográfico de macacos-prego, constituindo-se como uma técnica de fácil aplicação, poddevendo ser considerada na investigação de problemas cardíacos para esta espécie silvestre...


Subject(s)
Animals , Cebus/anatomy & histology , Heart/anatomy & histology , Heart , Radiography, Thoracic/veterinary , Thoracic Vertebrae , Animals, Wild/anatomy & histology , Diagnostic Techniques, Cardiovascular/veterinary
12.
Arq. bras. oftalmol ; 77(5): 324-326, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-730385

ABSTRACT

Here we report the occurrence of pale yellowish perivascular preretinal dots in 12 patients with ocular syphilis. A case series of these patients was examined between March and October 2012 at the Uveitis Sector of Universidade Federal de São Paulo. After diagnostic confirmation of syphilis, fundus photographs and optical coherence tomography (OCT) were performed to verify the localization of the dots, and patients were treated with IV crystalline penicillin for 14 days. The study comprised 11 men (91.6%), 19 eyes, median presentation age of 38.1 years, and panuveitis as the main clinical manifestation (seven patients, 58.3%), being bilateral in four. Ten patients were taking oral prednisone (83.3%). Serum panels performed by the Venereal Disease Research Laboratory (VDRL) showed positive results in eight patients (66.7%), whereas VDRL cerebrospinal fluid (CSF) tests were negative in seven of nine collected (77.8%). However, serum FTA-Abs was positive in 100% of patients, and eight patients (66.7%) had HIV infection. The best corrected visual acuity (BCVA) presented after treatment improved in 10 eyes (55.6%), did not change in seven eyes (38.9%), and worsened in one eye (5.6%). Although not yet acknowledged in the literature as a typical manifestation of ocular syphilis, these are very common findings in clinical practice. We believe that preretinal dots are due to perivasculitis secondary to treponema infection. It is important recognize them and remember that syphilis can present in several forms, including the one presented in this study.


Relatar a ocorrência de pontos amarelo-esbranquiçados perivasculares pré-retinianos em 12 pacientes com sífilis ocular. Série de casos de 12 pacientes examinados entre março e outubro de 2012 no setor de uveítes da UNIFESP. Após confirmação diagnóstica de sífilis ocular, retinografias e OCT (optical coherence tomography) foram realizados para verificar a localização dos pontos e os pacientes foram tratados com penicilina cristalina IV por 14 dias. Dados demográficos incluíram 11 homens (91,6%), 19 olhos, mediana de idade de 38,1 anos, e a manifestação clínica principal foi panuveíte (7 pacientes, 58,3%), sendo bilateral em 4. Dez fizeram uso de prednisona oral (83,3%). VDRL (Venereal Disease Research Laboratory) sanguíneo foi positivo em 8 pacientes (66.7%), VDRL no líquor foi negativo em 7 de 9 coletados (77,8%), FTA-Abs sanguíneo foi positivo em 100% e 8 pacientes (66,7%) eram HIV positivos, AV após tratamento melhorou em 10 olhos (55,6%), não se alterou em 7 (38,9%) e piorou em 1 olho (5,6%). Embora ainda não reconhecida na literatura como uma manifestação típica da sífilis ocular, este achado é muito comum na prática clínica. Acreditamos que esses pontos são devidos a perivasculite secundária à infecção pelo treponema. É importante os reconhecer e lembrar que a sífilis pode se apresentar de várias formas, incluindo essa apresentada aqui.


Subject(s)
Humans , Uveitis , Syphilis Serodiagnosis , Retina , Eye Infections, Bacterial , Panuveitis , Uveitis, Posterior/diagnosis , Tomography, Optical Coherence
13.
Biosci. j. (Online) ; 30(5): 1428-1437, sept./oct. 2014. tab, ilus
Article in Portuguese | LILACS | ID: biblio-946643

ABSTRACT

A avaliação dos efeitos da competição das plantas daninhas sobre o crescimento de culturas como milho e soja é efetuada por meio de ensaios em ambientes protegidos para maior precisão experimental e segurança nos resultados obtidos. Esses ensaios geralmente são feitos em recipientes (vasos) onde se testam os efeitos desejados em épocas após plantio. O tamanho do vaso quando pequeno pode limitar o desenvolvimento da planta pelo volume de substrato neles contido. No entanto, essa limitação está diretamente relacionada às espécies em desenvolvimento e ao tempo de avaliação. Assim objetivou-se com este trabalho verificar o efeito do volume de vasos na capacidade competitiva das plantas de picão-preto, milho e soja em diferentes épocas de avaliação. O milho apresentou-se mais competitivo com o picão-preto que a soja tanto nos diferentes tamanhos de vaso quanto nas diferentes épocas. Dentro do intervalo testado, recomenda-se o uso de vasos com volume de 16 dm3, devido à baixa tendência de estabilização das curvas do modelo proposto. Por este motivo também, pode-se afirmar que intervalos iguais ou inferiores a 60 dias são inadequados para os ensaios de competição das plantas de picão-preto com milho ou soja.


The evaluation of the effects of weed competition on growth from crops like corn and soybeans is done by testing in protected environments for increased accuracy and confidence in experimental results. These tests are usually done in containers (pots) where they test their desired times after planting. The small size of the vessel when could limit development of the plant the volume of the substrate contained therein. However, this limitation is directly related to the species in the development and evaluation time. Thus the objective of this work is to verify the effect of the volume of vessels in the competitive ability of plants black jack, corn and soybean at different sampling times. The corn had become more competitive with black jack soybean so that the vessel in different sizes and at different times. Within the range tested, it is recommended the use of vessels with a volume of 16 dm 3, due to the low tendency to stabilize model curves. For this reason, too, can say what intervals not exceeding 60 days are inadequate for field trials of plants black jack with corn or soybeans.


Subject(s)
Glycine max , Zea mays , Bidens , Plant Weeds , Agriculture
14.
Arq. bras. oftalmol ; 77(4): 214-218, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-728665

ABSTRACT

Purposes: To validate a teleophthalmology mobile system aimed at improving and providing eye urgency screenings in remote and poor area settings in Brazil. The system enables one or more ophthalmologists to remotely examine a patient's condition and submit a decision describing the gravity of the case. If necessary, the patient can be forwarded to a hospital for further consultation. Methods: A cellphone (Nexus One model, with a 5 megapixel camera) was used to collect data and pictures from 100 randomly selected patients at the Ophthalmology Emergency Room located at the General Hospital of the Federal University of São Paulo (UNIFESP). Data was then sent remotely to an online recording system to be reviewed by an ophthalmologist who provided feedback regarding the state of ocular urgency. Results were then compared to the gold standard diagnosis provided at the hospital. Results: The diagnosis of urgency was given by two ophthalmologists: one in the hospital (gold standard) and one remotely. When we compared both diagnoses we obtained results of 81.94% specificity, 92.85% sensitivity, and 85% accuracy, with a negative predictive value of 96.72%. This work also included a processing time analysis, resulting in an average time of 8.6 min per patient for remote consultations. Conclusions: This study is the first that has used only a cellphone for diagnosing the urgency of ocular cases. Based on our results, the system can provide a reliable distinction between urgent and non-urgent situations and can offer a viable alternative for the servicing of underprivileged areas. In screening techniques, the most important outcome is to identify urgent cases with a high level of sensitivity and predictive negative value. Thus, our results demonstrate that this tool is robust and we suggest that a major study aimed to verify its efficiency in resource-poor areas should be initiated. .


Objetivos: Validar um sistema de teleoftalmologia móvel que tem como objetivo fornecer triagem de urgências oftalmológicas em áreas remotas e desfavorecidas do Brasil. O sistema permite que um ou mais oftalmologistas possam examinar remotamente a condição do paciente e apresentar uma decisão que descreve a gravidade do caso. Se necessário, o paciente será encaminhado ao hospital para consulta. Métodos: Através de um celular e sua câmera (modelo Nexus One com câmera de 5 megapixel), foram coletados dados de 100 pacientes aleatoriamente selecionados no pronto socorro oftalmológico da Universidade Federal de São Paulo (UNIFESP) e enviados remotamente para um sistema online, por meio do qual um oftalmologista analisou-os e enviou um diagnóstico sobre a gravidade dos casos. Os resultados enviados foram comparados com o padrão ouro que foi fornecido pelo médico no hospital. Resultados: O diagnóstico foi fornecido por dois oftalmologistas: um no hospital (padrão outro) e outro remotamente. Comparando os resultados dos diagnósticos, foi obtido 81,94% de especificidade, 92,85% de sensibilidade, acurácia de 85% e um valor preditivo negativo de 96,72%. Também foi testado o desempenho do sistema, resultando num tempo de processamento do atendimento remoto em média de 8,6 minutos por paciente. Conclusões: Esta solução de baixo custo é a primeira da literatura que utiliza apenas o telefone celular para detectar urgências oftalmológicas. Com base nos resultados, o sistema consegue oferecer um atendimento confiável, diferenciando os casos de urgências e não urgências através da plataforma de telemedicina. Como ferramenta de triagem, o mais importante é identificar os casos de urgência (ter alta sensibilidade). Assim, os resultados obtidos demonstram que a ferramenta ...


Subject(s)
Humans , Cell Phone , Eye Diseases/diagnosis , Telemedicine/methods , Brazil , Computer Communication Networks , Predictive Value of Tests , Remote Consultation/methods , Sensitivity and Specificity , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL